UL Supervisory Switch for OS&Y Gate Valve

HOS

  • -

  • -

  • -

  • -

UL OS&Y Gate Valve Supervisory Switch for tamper detection to meet NFPA Compliance

The Model HOS is mainly used in Fire Sprinkler system & Fire Suppression system to monitor the open/close status of an OS&Y (outside screw and yoke) gate valve, typically to ensure they are open and the system is ready to deliver water in case of a fire.

Application of UL Supervisory Switch for OS&Y Gate Valve

Application of Hants UL Supervisory Switch for OS&Y Gate Valve

New Product

  • Installation Position: The switch should be mounted in a way that does not interfere with the normal operation of the valve.
  • Adjustment Requirements: The switch should be set to activate after two revolutions of the valve control, or when the stem has moved no more than one-fifth of the distance from its normal position.

Key Features and Benefits UL Supervisory Switch for OS&Y Gate Valve

  • Sprinkler System Monitoring: Ensures the main water supply valve is open so water can reach the sprinkler heads in the event of a fire. It is Common in wet-pipe, dry-pipe, and pre-action systems.
  • Tamper Detection: Alerts building management or fire services if someone accidentally or deliberately turns the valve off. It prevents dangerous situations where a fire could occur but the water is shut off.
  • Fire Alarm Integration: Connects to the fire alarm control panel (FACP). Triggers a supervisory (trouble) signal, not a fire alarm, so corrective action can be taken before an emergency.
  • Compliance with Codes: Required by NFPA 13 and NFPA 72 codes for fire protection systems. It helps meet the insurance and fire marshal requirements.

Frequently Asked Questions(FAQ) about UL Supervisory Switch for OS&Y Gate Valve

Q:If a site without Supervisory Switch for OS&Y Gate valve, any potential problems might occur?

  • Undetected Valve Closure: Without a supervisory switch, there’s no way to detect this remotely. No warning signal is sent to the fire alarm panel or monitoring center. During a fire, no water will be available to suppress flames which is increasing damage, danger to life, and possible fatalities.
  • Violation of Fire Codes: NFPA 13 (Standard for the Installation of Sprinkler Systems) and NFPA 72 (National Fire Alarm and Signaling Code) require valve supervision. Without a supervisory switch, the system may not pass fire inspections.

Catalogue(Model UL-HSO) Add to Inquiry

Related Products


  • UL Pressure Reducing Valve

    UL Pressure Reducing Valve

  • UL Grooved Type Butterfly Valve with Signal Switch

    UL Grooved Type Butterfly Valve with Signal Switch

  • UL OS&Y Gate Valve

    UL OS&Y Gate Valve

  • UL NRS Gate Valve

    UL NRS Gate Valve

  • UL Swing Check Valve

    UL Swing Check Valve

  • UL Wafer Type Butterfly Valve

    UL Wafer Type Butterfly Valve

  • UL Grooved Type Swing Check Valve

    UL Grooved Type Swing Check Valve

  • UL Grooved End Type OS&Y Gate Valve

    UL Grooved End Type OS&Y Gate Valve

  • UL Bronze Signal Type Butterfly Valve

    UL Bronze Signal Type Butterfly Valve

  • UL Test and Drain Valve

    UL Test and Drain Valve

  • UL Dry Barrel Fire Hydrant

    UL Dry Barrel Fire Hydrant

  • UL Pressure Restricting Angle Hose Valve

    UL Pressure Restricting Angle Hose Valve

  • UL Waterflow Detector

    UL Waterflow Detector

  • UL Hose Angle Valve

    UL Hose Angle Valve

X
UL Supervisory Switch for OS&Y Gate Valve
UL Supervisory Switch for OS&Y Gate Valve
Specification